Nanjing Color Science Co.,Ltd
Section

Products

Rhodamine 6GD

    • Product Name: Rhodamine 6GD
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales3@liwei-chem.com
    • Manufacturer: Nanjing Color Science Co.,Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 113376
    Product Name Rhodamine 6GD
    Synonyms Rhodamine 6G; Rhodamine 6GDN; Basic Red 1
    Cas Number 989-38-8
    Ci Name C.I. Basic Red 1
    Ci Number 45160
    Dye Class Xanthene
    Molecular Formula C28H31ClN2O3
    Molecular Weight 479.02 g/mol
    Appearance Dark red to reddish-brown powder
    Solubility Soluble in water, ethanol, and methanol
    Absorption Maximum About 525-530 nm
    Emission Maximum About 545-555 nm
    Fluorescence Color Yellowish-red to orange-red
    Fluorescence Quantum Yield About 0.95 in ethanol
    Storage Condition Store protected from light, dry, and at room temperature

    As an accredited Rhodamine 6GD factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Rhodamine 6GD is packaged in a sealed, light-resistant 25 kg fiber drum with an internal polyethylene liner.
    Container Loading (20′ FCL) Rhodamine 6GD drums are palletized, secured, and loaded into a sealed 20-foot FCL container for safe ocean freight.
    Shipping Ship Rhodamine 6GD in well-closed, properly labeled containers, protected from moisture, light, and heat. Follow the SDS and applicable DOT/IATA/IMDG regulations; verify hazard classification, labeling, and documentation before transport. Use sturdy outer packaging and secure closures to prevent leaks. Do not load with incompatible oxidizers or strong acids.
    Storage Store Rhodamine 6GD in a tightly closed, original container in a cool, dry, well-ventilated area, protected from light, heat, moisture, and ignition sources. Keep away from oxidizing agents and incompatible materials. Avoid dust generation, label clearly, and follow local regulations and safety data sheet requirements.
    Shelf Life Rhodamine 6GD has a shelf life of several years when stored cool, dry, dark, and tightly sealed in its original container.
    Application of Rhodamine 6GD
    Rhodamine 6GD enters flashlamp-pumped and frequency-doubled Nd:YAG-pumped dye laser systems only after removal of insoluble particulates and water. A circulating dye cell with a 0.5 mm pump depth and a linear flow velocity of 5–10 m/s is charged with a methanolic solution at 0.2–0.5 mmol/L, depending on whether the resonator is configured for narrowband tuning or broadband operation. Methanol gives a lasing maximum near 570 nm, while a 1:1 methanol/ethylene glycol mixture extends the tuning range but increases viscosity and thermal lensing. Solutions are vacuum filtered through a 0.1 µm PTFE membrane and nitrogen-sparged for at least 20 min before use. Dissolved oxygen above 5 ppm lowers slope efficiency because intersystem crossing populates the triplet manifold. Output coupler transmission between 20% and 40% balances threshold and slope. Thermal gradients across the pumped volume produce a lens that is compensated in an astigmatically folded cavity with a mirror radius of 100–150 mm; residual divergence greater than 2 mrad indicates that the thermal lens in the dye solvent is outside the compensating design window. Service life is judged by threshold rise rather than fixed time: a threshold increase of 30% from the clean-cuvette reference triggers solvent discharge and replacement of the gain medium in a closed loop. Dissolved metal cations, particularly iron, reduce fluorescence quantum yield; therefore all wetted parts are stainless 316L or borosilicate glass. The final output is used in high-resolution spectroscopy, laser-induced fluorescence calibration sources, and ultra-short pulse amplification when seeded with a mode-locked oscillator.

    Why Does a 532 nm Excitation Source Require Spectral Filtering Beyond 545 nm in Dense Spray Seeding?

    In planar laser-induced fluorescence and particle image velocimetry, Rhodamine 6GD is introduced as a tracer at 0.1–5 mg/L of the carrier liquid to re-emit a Stokes-shifted band centered near 555–580 nm, depending on the solvent and pH. The tracer is first dissolved in a polar co-solvent such as methanol or dimethylformamide at 0.5–1.0 g/L, then injected through a positive-displacement dosing pump into the primary liquid supply line. For aqueous spray tunnels, a water-miscible co-solvent prevents dye aggregation; the coalescing filter upstream of the atomizer must be inert, because cellulose acetate membranes extract the dye and cause concentration drift. The imaging train uses a bandpass filter of 550–610 nm and a longpass edge filter at 545 nm to reject Mie scattering at the excitation wavelength. Gated intensifier settings below 100 ns are required when fuel-swirl or diesel injection is under investigation, because natural flame luminosity interferes with the dye emission. The concentration in the interrogation plane is calibrated by in situ laser-induced fluorescence against a cuvette of known dye concentration; pixel-to-pixel flat-field correction uses a dye-doped fused-silica cell inserted into the object plane before each run. Batch-to-batch variance in dye purity modifies emission intensity by 5–10%; therefore a fluorescence ratio at 530 nm to 550 nm is checked on receipt and each diluent batch is normalized. The downstream output includes quantitative equivalence ratio distributions in spark-ignition engines, film thickness in coating sprays, and droplet size validation in agricultural nozzle testing. Published data for high-pressure diesel sprays with ambient gas temperatures above 800 K is limited, because thermal degradation of the xanthene chromophore reduces signal below the CCD noise floor faster than thermometry can compensate.Cationic acrylic exhaust dyeing with 6GD is initiated at 60°C in a high-temperature exhaust dyeing machine, not by dry blending or downstream coating. The dyebath is set with 0.2–1.5% owf Rhodamine 6GD, 1.0–3.0 g/L sodium acetate, and sufficient acetic acid to hold pH at 4.5–5.0. A quaternary ammonium retarder at 0.5–1.5% owf is added before the dye to reduce strike rate. The goods are ramped at 1°C/min to 98°C and held for 45–60 min in a machine equipped with an internal reel speed of 150–250 m/min. The terminal shade on polyacrylonitrile is a brilliant fluorescent pink-red; polyester and cotton are not substantive to this cationic dye without prior modification. After dyeing, residual unfixed dye is removed by overflow rinsing at 60°C and a nonionic detergent. Anionic fixatives are excluded from the after-treatment, because precipitation with the residual cationic dye produces a dull surface film. Fastness testing under ISO 105-B02 commonly shows a grade below 4 on the blue wool scale at 1.0% owf, making the dye unsuitable for outdoor acrylic awnings unless a hindered amine light stabilizer is applied. Wash fastness tested to ISO 105-C06 A2S at 40°C remains in the 3–4 range for medium depths. The downstream products are high-visibility acrylic knitwear, faux fur, and craft yarns where bright fluorescence compensates for moderate lightfastness.
    Test designationCondition assessedControl parameter for 6GD on acrylic
    ISO 105-B02Xenon-arc light fastnessBlue wool grade <4; UV absorber required for outdoor exposure
    ISO 105-C06 A2SDomestic/commercial washing at 40°CMultifibre staining and shade change measured after 30 min
    ISO 105-X12Rubbing fastness, dry and wetDry/wet differential used to specify cationic aftertreatment

    When Roller-Mill Inks Cross a 40 µm Wedge Gap, Low-Shear Viscosity Must Stay Below 200 mPa·s

    In solvent-borne flexographic and gravure ink bases, Rhodamine 6GD is dissolved into a nitrocellulose/polyurethane binder before letdown to a press viscosity of 18–25 s on a DIN 4 cup per ISO 2431 at 25°C. The dye concentration in the finished liquid ink is 0.5–1.5 wt% of non-volatile solids; higher loadings increase viscosity non-linearly and produce crystallization in the anilox cells during press stoppage. Methyl ethyl ketone and ethyl acetate are preferred over ethanol-only systems because the dye has limited solubility in anhydrous ethanol at room temperature. The solution is dispersed with a high-speed dissolver at 4000–5000 rpm for 20 min, then filtered through a 10 µm polypropylene bag filter before charging the press sump. On a narrow-web press with ceramic anilox rolls of 400–600 lpi, the ink must retain fluorescent emission after top-coating; a water-based overprint varnish can quench emission if its pH exceeds 8 and opens the lactone ring. The security printing version is formulated at higher dye loading and paired with a violet or ultraviolet excitation source; verification under ISO 2836 evaluates image security properties but does not certify the material for indirect food contact. Migration into packaged food is not permitted because Rhodamine 6GD lacks a specific clearance under FDA 21 CFR or the positive list in EU 10/2011. The finished printed articles include tamper-evident labels, event tickets, and anti-counterfeit patches where a visible pink-red fluorescence is read by camera-based authentication systems.Melt coloration of transparent polymethyl methacrylate and styrene-acrylonitrile with Rhodamine 6GD is limited to below the thermal degradation threshold of the xanthene chromophore. The dye is first dispersed as a 1–5 wt% masterbatch in a PMMA or styrenic carrier using a twin-screw extruder with a screw diameter of 25 mm and an L/D ratio of 25:1. The barrel temperature is maintained between 180°C and 210°C, because visual dulling and emission loss occur when melt residence time exceeds 5 min above 220°C. Polymer pellets are pre-dried at 80°C for 4–6 h when the ambient relative humidity exceeds 60%, to prevent hydrolysis of the carrier and bubble formation in transparent parts. Letdown ratios from 50:1 to 100:1 produce a transparent red-pink sheet when the masterbatch is matched to the refractive index of the matrix; titanium dioxide and other scattering pigments are omitted because they block fluorescence emission. Injection molding is performed with a clamp force sufficient to maintain a mold surface temperature of 60–80°C, and the screw backpressure is kept below 10 bar to reduce shear heating. Under ISO 1133-1, the melt flow rate of the let-down compound is measured to confirm that the dye has not catalyzed the degradation of the carrier. The final components are decorative transparent diffusers, instrument covers, and visual inspection trays in non-food contact applications. Published data for this specific configuration is limited for outdoor glazing, because the dye has a light fastness under concentrated xenon exposure that is significantly lower than that of mineral pigments.

    Optical Efficiency Loss Mechanisms in PMMA Waveguide LSC Prototypes

    During bulk polymerization of methyl methacrylate, Rhodamine 6GD is dissolved as a filtered MMA concentrate and incorporated at 50–300 ppm by weight relative to monomer. The monomer is freed of inhibitor by activated alumina or distillation, mixed with 0.02–0.05 wt% azobisisobutyronitrile, and the dye is introduced through a 0.2 µm membrane. The mixture is polymerized in a water-jacketed glass cell at 40–55°C for 12–24 h, followed by post-cure at 80°C for 2 h to reduce residual monomer below 1%. The edge faces are polished with cerium oxide to an optical finish, and edge-mounted photovoltaic cells capture the internally reflected emission. The dominant loss mechanism is self-absorption: the overlap between the absorption tail and emission band causes repeated re-emission events, and each waveguide internal reflection event has a surface scattering loss that depends on edge roughness. Increasing the dye loading above 300 ppm raises initial absorbance but lowers edge efficiency because the re-absorption cascade lengthens the mean photon path length and terminates in non-radiative relaxation. The optical efficiency of small prototypes is commonly reported below 5% under ASTM G173 AM1.5 spectral distribution, but published data for full-scale building-integrated modules is limited. Long-term stability is measured by monitoring the dominant emission peak under continuous xenon irradiation through PMMA; fading of the dye is the primary degradation mode, not polymer yellowing. The final parts are research-scale waveguides and demonstration panels for building-integrated photovoltaic concepts, not mass-produced energy devices.
    Free Quote

    Competitive Rhodamine 6GD prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to sales3@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: sales3@liwei-chem.com

    Inquiry

    Get Free Quote of Nanjing Color Science Co.,Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Rhodamine 6GD is introduced as a refined xanthene dye corresponding to C.I. Basic Red 1, CAS 989-38-8, with the GD suffix denoting a supplier-specific purification grade rather than a separate Colour Index species. The material is supplied as a deep red-brown to dark green crystalline powder, with a molecular formula of C28H31ClN2O3 and a nominal molecular weight of 479.01 g/mol. Representative commercial certificates of analysis list dye content not less than 95.0% by UV/Vis spectrophotometry at the absorption maximum in methanol, loss on drying at 105 °C to constant mass not more than 1.0%, and water-insoluble matter below 0.2%. The chloride counterion is standard; perchlorate and ethyl sulfate grades are available for solvent-dye applications requiring high electrolyte purity.

    The GD designation should be read as a vendor-specific refined grade, not a distinct isomer; its absorption and emission maxima are within 1 nm to 2 nm of parent Rhodamine 6G values. The practical distinction lies in lot-to-lot consistency of residual chloride, water content, and non-fluorescent coloured impurities. For laser-grade lots, additional optical-density acceptance criteria are applied at 530 nm and 350 nm; the absorbance ratio between these wavelengths provides an index of coloured and non-fluorescent impurities. Residual chloride is determined by ion chromatography and is normally controlled between 0.5% and 2.0%. Wavelength calibration of release spectrophotometers is performed according to ASTM E275-08(2022). Published data for this specific configuration is limited outside vendor certificates of analysis.

    What Limits Direct Substitution of Rhodamine 6GD for Rhodamine B in Confocal Imaging Channels?

    In epifluorescence microscopy and confocal imaging, filter sets and dichroic mirrors are matched to dye emission. Rhodamine 6GD in ethanol exhibits an absorption maximum of 530 nm and an emission maximum of 552 nm; Rhodamine B in the same solvent absorbs at 543 nm and emits at 565 nm. The 13 nm emission separation is sufficient to place Rhodamine 6GD in a 575/30 nm bandpass channel, whereas Rhodamine B normally requires a 585/40 nm or 595/50 nm channel. Users must verify the excitation laser line: Rhodamine 6GD is efficiently excited at 532 nm, while Rhodamine B is more often excited at 543 nm or 561 nm. Direct substitution without changing the dichroic cut-off may reduce collection efficiency by 30% to 50% depending on the cube specification.

    Laser dye cell behaviour provides a production-scale benchmark for Rhodamine 6GD. With a 514.5 nm argon-ion pump, a dye concentration of 0.1 g/L to 0.5 g/L in ethanol, and a 0.3 mm jet-stream dye cell, the tuning curve extends from approximately 560 nm to 610 nm. Peak conversion efficiency under these conditions is typically 20% to 30% when the output coupler reflectivity is set between 70% and 80%. Oxygen quenching and thermal lensing require nitrogen purging of the dye reservoir and control of pump irradiance at the cell wall. Pre-drying at 60 °C under vacuum for 12 h reduces water content that otherwise depresses quantum yield by 5% to 10%. Batch-to-batch variation in residual chloride can shift the free-running wavelength by 2 nm to 3 nm; dye solutions are usually prepared fresh daily and stored in borosilicate reservoirs.

    Solvent-Dependent Photophysical Data and Counterion Purity Control

    Solvent polarity and hydrogen-bonding capacity affect the absorption and emission maxima of Rhodamine 6GD. The values in Table 1 are typical for the chloride salt at 25 °C and a dye concentration below 0.01 g/L, where dimer formation is negligible. Spectra are recorded with a scanning double-beam spectrophotometer using a 1 cm quartz cuvette and a fluorescence spectrometer with bandpass of 2 nm to 5 nm; wavelength accuracy is checked against ASTM E388 or equivalent internal methods.

    Table 1. Typical spectral values for Rhodamine 6GD in selected solvents at 25 °C
    SolventAbsorption maximumEmission maximumRelative quantum yieldFluorescence lifetime
    Ethanol, anhydrous530 nm552 nm0.953.9 ns
    Methanol, HPLC grade528 nm550 nm0.943.8 ns
    Water, pH 6.0526 nm551 nm0.953.8 ns

    In exhaust dyeing of polyacrylonitrile, Rhodamine 6GD is applied as a basic dye with cationic affinity for anionic sulfonate sites in the fibre. A production-scale package-dyeing machine operating at a 10:1 liquor-to-fibre ratio and a pH of 4.5 to 5.5 is charged with 1.0% to 2.0% dye on weight of fibre, sodium acetate buffer, and a nonionic levelling agent. The temperature is raised from 70 °C to 100 °C at 1 °C/min and held for 30 min to 45 min. Filtration through 25 µm mesh is necessary before circulation through the yarn package to prevent particulates from depositing on the package surface. Alkaline pH above 8.0 and temperatures above 105 °C are avoided because the carboxyethyl ester hydrolyzes and produces shade drift. Light fastness of the resulting dyeing is assessed by ISO 105-B02:2014, and wash fastness by ISO 105-C10:2006.

    Thermoplastic masterbatch production uses Rhodamine 6GD at 0.1% to 1.0% by weight in poly(methyl methacrylate) or polycarbonate. Dispersion is carried out in a co-rotating twin-screw extruder with an L/D ratio of 40:1 and barrel temperatures of 180 °C to 220 °C. The dye remains soluble in the amorphous phase up to 0.5% loading; above this loading, aggregation produces a shoulder at 570 nm to 580 nm in the absorption spectrum and lowers fluorescence quantum yield. Extrusion at 220 °C for residence times above 4 min causes 5% to 10% loss of fluorescence intensity. Venting at -0.08 MPa and pre-drying the polymer at 80 °C for 4 h reduce hydrolytic degradation. Fluorescent films prepared from these compounds are evaluated by ASTM D638-14 for mechanical properties and by ASTM E991 for fluorescence measurement. Published data for this specific configuration is limited beyond vendor technical bulletins.

    When Alkaline Hydrolysis of the Carboxyethyl Ester Restricts Aqueous Tracer Reuse

    Rhodamine 6GD contains a carboxyethyl ester substituent that is vulnerable to alkaline hydrolysis to the carboxylic acid. In hydrological tracing, injection solutions are typically prepared at 1 g/L to 10 g/L and adjusted to pH 5.5 with dilute acetic acid. At pH above 8.0 and temperature above 40 °C, the absorption maximum shifts by 5 nm to 8 nm, and fluorescence intensity can decrease by 10% to 30% over 24 h. Published data for this specific configuration is limited, but the degradation pathway is inferred from the known ester hydrolysis behaviour of Rhodamine 6G. The dye should not be blended with sodium hydroxide, sodium carbonate, or amine-based additives because the resulting pH shift accelerates hydrolysis. Inline fluorometers used for production-scale injection monitoring are calibrated at 530 nm excitation and 550 nm emission; sensor fouling is removed with methanol, and hypochlorite bleach is avoided because it rapidly chlorinates and decolourizes the xanthene ring.

    Fixed-cell staining protocols with Rhodamine 6GD use an aqueous working solution of 0.1 µg/mL to 1 µg/mL in phosphate-buffered saline at pH 7.0. The dye stains mitochondria and nucleoli but is not considered as specific as Rhodamine 123; therefore it is used as a counterstain or tracer when green fluorescein channels are already occupied. Sections are mounted in anti-fade medium containing n-propyl gallate, and emission is collected at 550 nm to 570 nm with 532 nm excitation. Photobleaching under 40× oil immersion at 35 mW illumination becomes significant after 10 min; acquisition should be completed within 5 min. Cationic adsorption to glass surfaces is reduced by adding bovine serum albumin at 0.1% w/v. Diluted working solutions should be prepared in borosilicate glass or polypropylene containers; compatibility data for polycarbonate storage are not established.

    Comparing Rhodamine 6GD, Rhodamine B, and Rhodamine 123 in Ethanol

    Direct comparison with other cationic xanthenes is necessary because all three dyes share a positive charge but differ in substituent pattern and spectral position.

    Table 2. Comparative data for three cationic xanthenes in ethanol
    ParameterRhodamine 6GDRhodamine BRhodamine 123
    Colour IndexC.I. Basic Red 1C.I. Basic Violet 10Not Colour Index listed for bioanalytical grade
    CAS number989-38-881-88-962669-70-9
    Absorption maximum in ethanol530 nm543 nm507 nm
    Emission maximum in ethanol552 nm565 nm529 nm
    Net charge at pH 7.0+1+1+1
    Hydrocarbon substituentEthylamino and methylDiethylaminoMethylamino and phenyl ring

    Rhodamine B contains a carboxylate acid function that can form a colourless lactone in acidic nonpolar media; Rhodamine 6GD has the carboxy group ethyl-esterified, which suppresses the lactone equilibrium and reduces pH sensitivity in the pH 4.0 to 7.0 range. Rhodamine 123 is used mainly as a mitochondrial membrane potential probe because of its smaller steric profile and cellular uptake. Rhodamine 6GD is therefore selected where red-shifted fluorescence relative to fluorescein is required and where the pH-dependent lactone behaviour of Rhodamine B causes unacceptable emission instability.

    Bulk storage of Rhodamine 6GD in fibre drums at 25 °C and relative humidity below 60% is specified; above this humidity, the powder absorbs moisture and compacts, requiring drying before weighing. The product is incompatible with strong oxidizing agents, strong alkalis, and amine-based additives. Spills are collected with vacuum equipment fitted with a HEPA filter to avoid dust formation; aqueous rinses are contained and treated with activated carbon because Rhodamine 6GD is not readily removed by conventional biological wastewater treatment. Safety data sheets refer to the substance under C.I. Basic Red 1 and CAS 989-38-8; local exposure limits may apply.

    Under EU REACH, C.I. Basic Red 1 is subject to registration where imported above 1 tonne/year; users must verify the supplier’s registration status and SVHC evaluation. RoHS applies only in electrical and electronic applications where the dye is incorporated into polymers at concentrations above 0.1%; no restriction is currently listed for this specific dye under the RoHS annexes.